What was found
MCI - FLT 270 - NO EMERGENCY DECLARED LANDING UNEVENTFUL. ON DESCENT INTO MCI, NR 2 OIL QTY STARTED TO DECREASE. ON APPROACH QTY WENT TO ZERO, OIL PRESSURE AND TEMPERATURE WERE WITHIN LIMITS. REPLACED NR 6 BEARING OIL SCAVENGE PUMPED PER PWA MM 72-50, DRAINED OIL TANK. REPLACED MAIN OIL FILTER PER MM 79-11-0. INSPECTED OIL CHIP DETECTORS PER MM 79-21-31, SERVICED OIL TANK TO FULL PER MM 12-13-11. OPS CHECK, LEAK CHECKS OK. ASSIGNED WATCH ITEM TO REPLACED MAIN OIL FILTER AT 50 HOURS PER MM 72-00-0-2A. (M)