As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SJO - Q-CHECK ITEM. FRAME WEB CRACKED AT BS 351.2 BETWEEN STR 19L AND STR 20L. DEFECT SIZE: LENGTH 0.375 INCH. REPLACED WEB AT BS 351.2 BETWEEN STR 18L AND STR 21L PER SRM 51-10-1 PAGE 5 AND SRM 51-30-2. SEE COOPESA W.O. M1-0003-1-133, VAM 100 NR 662. (X)