What was found
SJO - DURING Q-CHECK, AN EXISTING SKIN REPAIR LOCATED AT BS 727A, STRINGER 8R, WAS REMOVED FOR INVESTIGATION. AREA WAS CLEANED, INSPECTED AND A PERMANENT REPAIR WAS INSTALLED AS PER SRM 53-30-3 FIGURE 6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - DURING Q-CHECK, AN EXISTING SKIN REPAIR LOCATED AT BS 727A, STRINGER 8R, WAS REMOVED FOR INVESTIGATION. AREA WAS CLEANED, INSPECTED AND A PERMANENT REPAIR WAS INSTALLED AS PER SRM 53-30-3 FIGURE 6. (M)