What was found
SJO - DURING C-CHECK, LEFT WHEEL WELL AT BS 726, WL 192 LBL 66 INCH STRINGER 18A SHEAR BEAM CRACKED. FABRICATED SHEAR BEAM IAW SRM 51-20-1 AND REPLACED SHEAR BEAM IAW SRM 51-10-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - DURING C-CHECK, LEFT WHEEL WELL AT BS 726, WL 192 LBL 66 INCH STRINGER 18A SHEAR BEAM CRACKED. FABRICATED SHEAR BEAM IAW SRM 51-20-1 AND REPLACED SHEAR BEAM IAW SRM 51-10-1. (M)