What was found
SJO - C-CHECK, FLOOR SUPPORT ANGLE CORRODED AT BS 270, WL 208.5, BETWEEN RBL 17 INCHE LBL 10 INCH. DEFECT SIZE, LENGTH 10 INCH, WIDTH 2 INCH. REPAIRED FLOOR SUPPORT ANGLE AT BS 270, WL 208.5, BETWEEN LBL 54 INCH TO RBL 25.5 INCH PER COOPESA EO COO-3-53-714-99 DATED DECEMBER 8, 1999. (M)