What was found
CRACK FOUND AT BS 1240 RBL 5.0 CLOSURE PANEL AT CANTED BULKHEAD COMMON TO APU FUEL FEED LINE/SHROUD FOUND CRACKED AROUND FASTENER LOCATION. CLOSURE PANEL REMOVED AND NEW PANEL INSTALLED PER SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FOUND AT BS 1240 RBL 5.0 CLOSURE PANEL AT CANTED BULKHEAD COMMON TO APU FUEL FEED LINE/SHROUD FOUND CRACKED AROUND FASTENER LOCATION. CLOSURE PANEL REMOVED AND NEW PANEL INSTALLED PER SRM 51-30-02.