DURING A-CHECK FOUND MAIN CEILING EMERGENCY LIGHT INOP STATION 500. REMOVED AND REPLACED EMERGENCY LIGHT ASSY IAW MM 33-51-07. OPS CHECKED SATISFACTORY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A-CHECK FOUND MAIN CEILING EMERGENCY LIGHT INOP STATION 500. REMOVED AND REPLACED EMERGENCY LIGHT ASSY IAW MM 33-51-07. OPS CHECKED SATISFACTORY.