What was found
CRACK ON CLOSURE BULKHEAD FIREWALL, NR 3 PYLON UNDER SLOT SEAL AREA. CRACK RUNS VERTICALLY APPROX 5 INCHES THEN SPLITS TO INBOARD SIDE. REPAIR CARRIED OUT REF SRM 54-10-03. CRACK STOP DRILLED PER SRM 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON CLOSURE BULKHEAD FIREWALL, NR 3 PYLON UNDER SLOT SEAL AREA. CRACK RUNS VERTICALLY APPROX 5 INCHES THEN SPLITS TO INBOARD SIDE. REPAIR CARRIED OUT REF SRM 54-10-03. CRACK STOP DRILLED PER SRM 51-10-01.