What was found
CRACK 8 INCHES LONG FOUND NR 2 ENG PYLON FORWARD LOWER SPAR FLOOR WEB AT STA 270, MID SPAR (PANEL 452CL). COMPLETED REPAIRS IAW BOEING REPAIR SCHEME DWGS PAO-LGB-02-00056F, 55F, 54H, 53F & 52H.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.