As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACKS FOUND ON THE CLIP AT FRAME STA 500/L, UPPER DECK SIDEWALL, AT CONNECTION TO STR 10-10A-11A-12. CRACKED CLIPS REMOVED & NEW ONES FABRICATED HF 7075T6 0.050 THK PER SRM 53-10-20 & SRM 51-40-03, FIG. 4. PROTECTED PER SRM 51-10-02 & INSTALL RIVETS PER SRM 51-30-02.