What was found
RUDDER RATIO LIGHT CAME ON DURING CLIMBOUT, 220KTS, FLAPS 1 DEGREE. RESEATED CONNECTOR TO RUDDER RATIO CONTROLLER AND SERVO ACTUATOR IAW AMM 27-21-00..
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RUDDER RATIO LIGHT CAME ON DURING CLIMBOUT, 220KTS, FLAPS 1 DEGREE. RESEATED CONNECTOR TO RUDDER RATIO CONTROLLER AND SERVO ACTUATOR IAW AMM 27-21-00..