What was found
DURING APPROACH, WHEN FLAPS 5 SELECTED, EICAS MESSAGE -FLAPS PRIMARY- THEN EICAS MESSAGE -FLAP DRIVE-. OBSERVED RT OUTBOARD L/E FLAP STUCK. STATUS MESSAGE -LE MULTIDRIVE-. QRH COMPLIED WITH. REMOVED AND REPLACED RIGHT OUTBOARD L/E POWER DRIVE UNIT PER AMM 27-81-03. OPS CHECK NORMAL.