What was found
ON GO AROUND, GEAR FAILED TO RETRACT. MAIN AND BODY GEAR REMAINED DOWN. NOSE GEAR SHOWED TRANSIT. EICAS: NOSE GEAR DOOR AND GEAR DISAGREE. GEAR LOWERED NORMALLY. COMPLIED WITH FIM PROCEDURE 32-61, TASK 866 FOR CMC MESSAGE 32676. NO DEFECTS NOTED. COMPLIED WITH FIM 32-61, TASK 886, FOR CMC 32716. NO DEFECT NOTED. COMPLIED WITH FIM PROCEDURE 32-61, TASK 869 FOR CMC 32679. NO DEFECTS NOTED. COMPLIED WITH FIM PROCEDURE 2-61 TASK 889 FOR CMC 32719. NO DEFECTS NOTED. COMPLIED WITH OPS CHECK OF NOSE DOOR SEQUENCING VALVE IAW AMM 32-34-07-404-006. OPS CHECK GOOD.