What was found
FLT DECK AUTO TEMP CONTROL DOES NOT REGULATE TEMPERATURE. PERFORMED DIM 21-64 FT 826 AND AMM 21-61-09, CLEANED FLIGHT DECK TEMP SENSOR & FOUND DIRTY IAW AMM 21-61-07 CLEANED TRIM VALVE FLT DECK CONNECTOR IAW AMM 21-51-00, BITE TESTED TEMP CONTROLLER, NO FAULT IAW AMM 21-61-00 FLT DECK TEMP CONTROL TESTED NORMAL.