What was found
FOUND THE MAIN DECK FLOORBEAM CORRODED AT BS 2240, RBL 67.01. REPAIRED DAMAGED AREA IAW EI T2017A53M-1230, REV 1. CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND THE MAIN DECK FLOORBEAM CORRODED AT BS 2240, RBL 67.01. REPAIRED DAMAGED AREA IAW EI T2017A53M-1230, REV 1. CHECKED NORMAL.