What was found
FOUND THE MAIN DECK FLOORBEAM CORRODED AT BS 2240, LBL 67. CORROSION REMOVED IAW SRM 51-10-02, REV 79. MEASURED REWORKED AREA ORIGINAL THICKNESS AND FOUND WITHIN ALLOWABLE LIMITS IAW SRM 53-00-51-1A-1, FIG 101, DETAIL II, REV 79. REPAIRED IAW SRM 51-20-01, REV 79.