What was found
RIGHT ENGINE HPSOV EICAS IN FL290 DURING CRUISE. ENGINE BLEED SHUTOFF IAW QRH, BLEED LIGHT STAYED ILLUMINATED. BLEED LIGHT GOES ON TO OFF. RT ENGINE HPSOV INSTALLATION, SENSING PIPE LINE, CONNECTOR AND HPC SELENOID SOUND. ON/OFF CHECK IAW AMM 36-11-07, VERIFIED HPSOV IS PROPERLY SECURED CLOSED IAW DDG 36-11-02-02 AND COMFIRMED LIGHT NO FLICKERING WITH ENGINE RUN IAW AMM 71-00-00.