What was found
EICAS FOR THE ENG BOTTLE NR 2. FOUND PRESSURE SWITCH ON THE BOTTLE INOPERATIVE, REMOVED AND REPLACED THE EXTINGUISHER BOTTLE IAW AMM 26-21-03-004-094. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EICAS FOR THE ENG BOTTLE NR 2. FOUND PRESSURE SWITCH ON THE BOTTLE INOPERATIVE, REMOVED AND REPLACED THE EXTINGUISHER BOTTLE IAW AMM 26-21-03-004-094. OPS CHECKED GOOD.