As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER LH ENGINE START EICAS DISPLAY " LH GEN OFF" CYCLED GEN CONT SWITCH PER QRH & CONT NORMAL(<P>FOUND IDG OIL LEVEL LOW. SUPPLIED OIL 1 QT I.A.W. A.M.M 12-13-03/301 ALSO IDG OIL LEVEL EXTERNAL LEAK CHECKED OK WITH ENG DRY MOTORING I.A.W. A.M.M. 71-00-00/501 </P><P>LP 1030471-M7 REPLAVED L/H GCU PER AMM 24-22-02 PERFORMED BPCU BITE TEST OK </P>)