What was found
FLIGHT DECK TEMPERATURE CONTROL DOES NOT WORK IN AUTOMATIC MODE. TEMPERATURE OSCILLATES BETWEEN 18-28 C, MANUAL CONTROL OKAY. CLEANED FLIGHT DECK TEMPERATURE SENSOR INLET AIR FILTER DUE TO DIRTY. ALL DOOR CLOSED AND OPERATION CHECKED TEMP CONTROL IN AUTO. ALL NORMAL INDICATION CHECKED OK, AS PER AMM 21-61-00.