What was found
FOUND CREW OXY PRESSURE INDICATION ABNORMAL. TRANSFERRED TO MDDR 138395, IAW MEL 35-11-02-01, CAT B. REMOVED AND REPLACED AVERAGING VOLTAGE UNIT & REGULATOR TRANSDUCER ON CREW OXY. THEN OPERATIONS CHECK OK, IAW AMM 35-11-04/401 & AMM 35-11-06/401. CLEARED MDDR NR 138395, REMOVED PLACARD, NOTIFIED TO MCC. T/I: DT 0548Z.