AFTER BLOCK OUT LT PACK OFF EICAS MESSAGE AND LEFT PACK OFF DISCRETE LIGHT FAIL TO ILLUMINATE WHEN LEFT PACK SELECTED OFF. CLEANED E/PLUG OF FLOW CONTROL VALVE AND THEN LT PACK OPERATIONS CHECK NORMAL, PER AMM 21-51-00.