What was found
CRACK DAMAGE ON THE STRINGER 2-9R, AT FWD SIDE OF STA 1960(<P>REPAIRED DAMAGED AREA IAW EI NO T2021A53M-920 REV 1. INSTALLED FASTENERS IAW SRM 51-40-02 REV 33 AND DWG NO 146U1961 SHEET 511 513 REV B, 146U1940 SHEET 173 REV -. CONDITION CHECK NORMAL AND JOB COMPLETED.</P>)