DURING FWD CARGO HEAT INHIBIT AFTER "FWD ARMED" SWITCH ACTIVATION FUCTION CHECK, FOUND RELAY (K00231) FAIL(<P>IAW WDM 21-43-11 REV 34 CHECK VOLTAGE, FOUND RELAY FAIL. IAW SWPM 20-81-22 REV 77 REMOVED AND REPLACED RELAY. IAW AMM 26-23-01-706-038 REV 132 PERFORM TEST, TEST PASSED</P>)