What was found
AFTER ENGINE START L GEN OFF CAUTION MESSAGE. RAN QRH, MESSAGE CLEARED(<P>PERFORMED BPCU BITE CHECK IAW 767 AMM 24-22-00. NO DEFECTS NOTED. PERFORMED ENGINE IDLE RUNS IAW B767 AMM 71-00-00 OPS CHECK GOOD</P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER ENGINE START L GEN OFF CAUTION MESSAGE. RAN QRH, MESSAGE CLEARED(<P>PERFORMED BPCU BITE CHECK IAW 767 AMM 24-22-00. NO DEFECTS NOTED. PERFORMED ENGINE IDLE RUNS IAW B767 AMM 71-00-00 OPS CHECK GOOD</P>)