As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
OVERWHELMING SMELL OF ELECTRICAL BURNING WHEN RUNWAY TURNOFF LIGHTS ARE ON(<P>RIGHT RUNWAY TURNOFF SWITCH CRIMPED CONNECTOR ISOLATION SHOWS SIGNS OF OVERHEATING. DEFERRED IAW MEL 33-42-03, MDDR 161134. PERFORMED AMM TASK 05-51-56 & TASK 21-00-01-102-03 PERFORMED. SEE ITEM 1 FOR CAUSE OF BURNING SMELL AND RECTIFICATION.</P> / <P>REMOVED AND REPLACED REQ TURN OFF LIGHT PANEL ASSY IAW AMM 20-11-00. OPS CHECK GOOD IAW AMM 33-42-00. THIS CLEARS DMI 161134.</P>)