What was found
EMP - RH HORIZONTAL STAB TIP FAIRING I/B CLOSURE WEB, FOUND CRACK.(<P>CRACK - WEB REPLACED AS PER SRM 51-10-01. NEW WEB HOLES TRANSFERRED AS PER SRM 51-40-05. NEW WEB INSTALLED AS PER SRM 51-40-02. NO FURTHER DEFECTS NOTED.</P>)