LEVEL 1 CORROSION AFT BULK CARGO DOOR SILL ENTRY FLOOR PLATE UNDER SCUFF PLATE UPPER SURFACE AT BS 1980 TO 2040. CORROSION REMOVED AND TREATED PER BOEING SRM 51-10-01 AND 51-10-02.