What was found
FOUND CORROSION ON TIE CLIPS STATION 1940 RT SIDE AT STRINGERS 28, 29, 30, 31, 32. REMOVED LEVEL ONE CORROSION AND TREATED IAW SRM 51-10-01. CORROSION FOUND TO BE WITHIN LIMITS OF SRM 53-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON TIE CLIPS STATION 1940 RT SIDE AT STRINGERS 28, 29, 30, 31, 32. REMOVED LEVEL ONE CORROSION AND TREATED IAW SRM 51-10-01. CORROSION FOUND TO BE WITHIN LIMITS OF SRM 53-10-01.