What was found
CORROSION ON FRAME AT STA 1241 NEAR STRINGER 1 LT. CORROSION BLENDED OUT, SURFACE SMOOTHED PER SRM 51-10-01 AND 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FRAME AT STA 1241 NEAR STRINGER 1 LT. CORROSION BLENDED OUT, SURFACE SMOOTHED PER SRM 51-10-01 AND 51-10-02.