What was found
CORROSION ON UPPER CHORD FLOORBEAM AT STA 960 BETWEEN AREA RBL AND LBL 32 TO 45. CORROSION REMOVED AND AREA TREATED PER SRM 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON UPPER CHORD FLOORBEAM AT STA 960 BETWEEN AREA RBL AND LBL 32 TO 45. CORROSION REMOVED AND AREA TREATED PER SRM 51-10-01.