What was found
LEVEL 2, U/D BS 520 LBL 54 TO LBL 61 FLOORBEAM FOUND CORRODED. REPLACED FLOORBEAM AT LBL 45 EXISTING SPLICE TO LT O/B END PER BOEING SRM 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2, U/D BS 520 LBL 54 TO LBL 61 FLOORBEAM FOUND CORRODED. REPLACED FLOORBEAM AT LBL 45 EXISTING SPLICE TO LT O/B END PER BOEING SRM 51-10-01.