What was found
LEVEL 2 - M/D BS 440 LBL 11 TO RBL 11 FLOORBEAM LOWER CHORD DRIP SHIELD SURFACE FOUND CORRODED. CORROSION REPAIRED PER BOEING SRM 51-10-01 AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 - M/D BS 440 LBL 11 TO RBL 11 FLOORBEAM LOWER CHORD DRIP SHIELD SURFACE FOUND CORRODED. CORROSION REPAIRED PER BOEING SRM 51-10-01 AND 51-40-02.