What was found
LEVEL 1 CORROSION, LWR SURFACE STA 970 WATER SERVICE STATION WATER TANK FILL VALVE HANDLE AT MOUNT. CORROSION REMOVED FOUND TO BE WITHIN LIMITS IAW BOEING SRM 53-10-01 FIG 1, REG MAT .130 NOW .111 TREATED AND PRIMED PER SRM 51-10-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 1 CORROSION, LWR SURFACE STA 970 WATER SERVICE STATION WATER TANK FILL VALVE HANDLE AT MOUNT. CORROSION REMOVED FOUND TO BE WITHIN LIMITS IAW BOEING SRM 53-10-01 FIG 1, REG MAT .130 NOW .111 TREATED AND PRIMED PER SRM 51-10-06.