What was found
LEVEL 1 CORROSION, UPPER LINK FORWARD FITTING (ON PYLON) BORE CORRODED NR 4 PYLON. REMOVED CORROSION IAW SB 54-2164. NON ROUTINE CARD S/N 6002.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 1 CORROSION, UPPER LINK FORWARD FITTING (ON PYLON) BORE CORRODED NR 4 PYLON. REMOVED CORROSION IAW SB 54-2164. NON ROUTINE CARD S/N 6002.