What was found
NR 2 HYD SYS FAILURE IN FLIGHT, HYD QTY WENT TO ZERO/LOW QTY LIGHT ON, ADP AND EDP LOW PRESS LIGHTS ON. FOUND CRACKED NR 2 EDP CASE. EDP BLANKING KIT INSTALLED IAW MM 29-11-05, MM 72-61-00. NO CONTAMINATION FOUND IN NR 2 SYS FILTERS. EDP CASE DRAIN FILTER REPLACED DUE TO SLIGHT METAL CONTAMINATION. SYSTEM FLUSHED, NIL FURTHER CONTAMINATION. LEAK CHECK OKAY PER MM 29-11-00.