What was found
NR 3 PYLON THROTTLE PUSH PULL CABLE ATTACH CHANNEL ADJACENT TO ANTI-ICE DUCT IS CRACKED. REPAIRED PER SRM 51-40-03 FIG 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 3 PYLON THROTTLE PUSH PULL CABLE ATTACH CHANNEL ADJACENT TO ANTI-ICE DUCT IS CRACKED. REPAIRED PER SRM 51-40-03 FIG 3.