What was found
FWD LOWER CARGO DOOR JAMB AFT LOWER SIDE LATCH PIN HOUSING IS GOUGED. BLENDED OUT GOUGE. NDT HFEC FOR CRACKS, NONE FOUND. TREATED AND PRIMED PER SRM 53-40-01 AND 51-00-02. NDT MANUAL 51-00-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD LOWER CARGO DOOR JAMB AFT LOWER SIDE LATCH PIN HOUSING IS GOUGED. BLENDED OUT GOUGE. NDT HFEC FOR CRACKS, NONE FOUND. TREATED AND PRIMED PER SRM 53-40-01 AND 51-00-02. NDT MANUAL 51-00-00.