What was found
RT WING NR 3 MAIN FUEL TANK JETTISON PUMP CUTOUT AREA OF REAR SPAR BONDING ATTACH POINT CORROSION. CORROSION REMOVED AND TREATED PER SRM 51-01-01, 51-10-02. BLEND OUT WITHIN SRM LIMIT 57-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING NR 3 MAIN FUEL TANK JETTISON PUMP CUTOUT AREA OF REAR SPAR BONDING ATTACH POINT CORROSION. CORROSION REMOVED AND TREATED PER SRM 51-01-01, 51-10-02. BLEND OUT WITHIN SRM LIMIT 57-10-01.