What was found
NR 1 PYLON O/B SIDE DIAGONAL BRACE CHAFED FWD END. EDDY CURRENT C/W PER NDT PART 6 54-40-03 WITHIN LIMITS PER SRM 54-40-01. BLEND OUT AREA SHOT PEENED AND TREATED PER SRM 54-40-01 AND 51-70-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 PYLON O/B SIDE DIAGONAL BRACE CHAFED FWD END. EDDY CURRENT C/W PER NDT PART 6 54-40-03 WITHIN LIMITS PER SRM 54-40-01. BLEND OUT AREA SHOT PEENED AND TREATED PER SRM 54-40-01 AND 51-70-00.