What was found
DURING SCHEDULED A INSPECTION NOSE GEAR WELL FLOORBEAM AT STATION X97 FOUND CRACKED. REPAIR STRAP INSTALLED PER DEHAVILLAND REPAIR DRAWING RD 8-53-5993 AS AN INTERIM REPAIR FOR 250 HOURS AT WHICH A PERMANENT REPAIR WILL BE INSTALLED. DEHAVILLAND HAD ISSUED REPAIR DRAWING RD8-53-6016 ALLOWING REPETITIVE INSPECTIONS AT 250 HOUR INTERVAL UNTIL PERMANENT REPAIR AT C CHECK IS ACCOMPLISHED. PERMANENT REPAIR APPLIED IN ACCORDANCE WITH REPAIR DRAWING RD8-53-6016 ON 17 JANUARY 2003 DURING C INSPECTION AT PIEDMONT AIRLINES. AIRCRAFT RETURNED TO SERVICE.