SDR PNSA990602

Service difficulty report · Pump · Swrngn SA227AC

Difficulty date
June 27, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N41NE
Make and model
Swrngn SA227AC
Aircraft serial
AC741B
Part
Pump
Part number
PV304426
Condition
Failed
Location
Lt Hyd Sys
Stage of operation
CR
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LT HYDRAULIC PRESSURE LIGHT ILLUMINATED DURING CRUISE. AIRCRAFT RETURNED TO ANC. MAINTENANCE FOUND SPLINES ON PUMP DRIVE SHAFT STRIPPED. PUMP WAS REPLACED AND TESTED OK. AIRCRAFT RELEASED FOR SERVICE.