What was found
DURING MX CHECK, CORROSION WAS FOUND ON UPPER SKIN PANEL OF WING CTR SECTION AT SEVERAL AREAS AROUND: BS 1240 RBL 30 CENTER WING UPPER SKIN, CORROSION BEYOND SRM LIMITS. REPAIRED IAW EO: 742-EO-57-6293 REV A. DWG 65B14552-1, DWG 65B14550-1, 65B01102-14, 65B10666-102, BL98.58, D6-35022 ITEM W-4 AND W-7.