As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INCOMING CONDITION HIGHLIGHTED DURING THE INSPECTION PROCESS. THE BOOSTER SPOOL HAS FRETTING ON SURFACE A (MORE THAN AMM & ESM LIMITS). KNOWN CONDITION. DR#01983965 WAS NOT APPROVED. FIRST TIME EXPOSURE OF THIS AREA FROM NEW MAKE. SERVICE RUN CONDITION, NOT A GE WALES INDUCED CONDITION. TO BE REPORTED IN LINE WITH MANDATORY REPORTING REQUIREMENT 145 AMC 20-8A 9.3.(J) ANY DEFECT IN A LIFE-CONTROLLED CRITICAL PART THAT CAUSES ITS RETIREMENT BEFORE THE COMPLETION OF ITS FULL SERVICE LIFE.