What was found
ACFT WAS BROUGHT INTO MX FOR MAST NUT TORQUE CHECK. NUT WAS REMOVED BY HAND. THE MAST WAS REMOVED AND SPACER TUBE WAS INSPECTED. THE PROJECTIONS ON THE FAYING SURFACE OF SPACER TUBE WERE WORN BEYOND ALLOWABLE LIMITS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ACFT WAS BROUGHT INTO MX FOR MAST NUT TORQUE CHECK. NUT WAS REMOVED BY HAND. THE MAST WAS REMOVED AND SPACER TUBE WAS INSPECTED. THE PROJECTIONS ON THE FAYING SURFACE OF SPACER TUBE WERE WORN BEYOND ALLOWABLE LIMITS.