What was found
DURING SCHEDULED MX, FOUND 2 STRUCTURAL CRACKS ALONG STA 270 BULKHEAD, BUTTLINE 8.5 LT, WATERLINE 81.6. CRACKS ORIGINATE FROM FASTENERS JOINING LT AFT NODAL BEAM SUPPORT PN 222-031-592-103 AND STA 270 BULKHEAD. NO PREVIOUS REPAIRS, ACFT OUT OF SERVICE.