As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ACFT MAIN FLOOR HONEYCOMB WAS CRUSHED ON THE LT, AFT SIDE APPROX 12" X 12". THIS WAS CAUSED BY STRETCHER WHEELS AND PATIENT LOAD NOT PROPERLY SUPPORTED BY MEDICAL FLOOR OVERLAY. THIS CABIN FLOOR REPAIR WAS COMPLETED AND DOCUMENTED ON FAA FORM 337 DATED 6/15/2012. THIS REPAIR WAS PERFORMED IAW FAA FORM 8110-3, DATED 6/8/2012. THIS ACFT HAS SINCE RETURNED TO SERVICE.