Service difficulty report · Floor Panel · Urocop EC135P1

Difficulty date
June 15, 2012
Submitted
June 21, 2012
Operation
Air carrier
Aircraft
N135SJ
Make and model
Urocop EC135P1
Aircraft serial
0054
Aircraft time
6,081 hours, 20,588 cycles
Part
Floor Panel
Part number
L533M1015102
Condition
Crushed
Location
Lt Aft Cabin
Stage of operation
AA
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ACFT MAIN FLOOR HONEYCOMB WAS CRUSHED ON THE LT, AFT SIDE APPROX 12" X 12". THIS WAS CAUSED BY STRETCHER WHEELS AND PATIENT LOAD NOT PROPERLY SUPPORTED BY MEDICAL FLOOR OVERLAY. THIS CABIN FLOOR REPAIR WAS COMPLETED AND DOCUMENTED ON FAA FORM 337 DATED 6/15/2012. THIS REPAIR WAS PERFORMED IAW FAA FORM 8110-3, DATED 6/8/2012. THIS ACFT HAS SINCE RETURNED TO SERVICE.