As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON POST FLIGHT, NOTICE FUEL ODOR, OPEN ENIGNE COWLING NOTICED FUEL LEAKING FROM HMU ASSY. THERE ARE TWO CRACKS ON FUEL PUMP HOUSING. LOCATED THE 5:00 IS 1.5 " IN LENGTH ON THE IN SERVICE PORT LOCATED AT THE 6:00 RT ABOVE THE DRAIN PORT LENGTH IS 1.0".