What was found
THE PILOT & MEDICAL CREW WERE ON THEIR WAY TO A SCENE LOCATION TO PICK UP A PATIENT WHEN APPROXIMATELY 4 MILES FROM THEIR DESTINATION, THE ENG CHIP LIGHT ILLUMINATED. THE PILOT NOTIFIED THE CREW THAT THEY WOULD NOT BE ABLE TO CONTINUE & PROCEEDED TO FIND A SUITABLE LANDING LOCATION. THE LANDING WAS UNEVENTFUL & MX WAS NOTIFIED OF THEIR LOCATION. ONCE THE MECHANIC ARRIVED, HE CHECKED THE ENG CHIP PLUG ONLY TO FIND A LARGE AMOUNT OF METAL PARTICLES. AFTER REVIEW OF THE MM & A CONVERSATION WITH TECHNICAL SUPPORT, IT WAS DECIDED THAT SEVERAL MODULES OF THE ENG WOULD NEED TO BE REPLACED. THIS ACFT IS CURRENTLY OUT OF SERVICE AWAITING PARTS.