What was found
DURING A PATIENT TRANSFER, THERE WAS A BURNT RUBBER ODOR IN THE CABIN & LOSS OF AIR CONDITIONING. AFTER LANDING AT GOOD SAM & OPENING THE TRANSMISSION COWLING, RUBBER DEBRIS COVERED THE DECKS & SEPARATED BELT WAS DISCOVERED. NO DAMAGE TO ROTATING COMPONENTS OR HYD BELT WAS FOUND. DEBRIS WAS CLEANED UP & THE MEL COMPLETED. THE FLIGHT CONTINUED TO SDL FOR FUEL & RETURN TO BASE FOR REPAIRS.